A1-01a Wireless Environmental Data Logger

Wireless monitor for temperature, humidity, light and vibration.
  • Setup alarm states and receive alarms via email, cell phone, pager, or landline. Even send the same alarm to multiple locations!
  • Power or internet outage notifications
  • Internal temperature, humidity, light and vibration sensors
  • External 4-20mA and 0-5V inputs
  • 2 Digital inputs
  • Battery or AC power
  • Up to 250' range
  • 250 Sample data buffer

General Purpose Pod

The A1-01a General Purpose Sensor Pod is designed for general environmental measurements. It provides several different internal sensors, as well as a screw terminal connector for connecting to a wide range of external analog sensors. The pod also includes a +5Vdc output to power external sensors.

In the event no gateway can be reached, individual pods will store up to 255 data points, until a connection is restored. The stored data will be transferred to the online account. Pods have a range of approx. 80m (250ft), and can also act as a repeater for other's signals.

Package Includes

·         A1-01 Pod

·         Pin-out Guide

·         AC Adapter

·         Standard Antenna

·         Wall Mounting Bracket

·         Batteries (3xAA)

Internal Sensors

·         Ambient Temperature

·         Vibration

·         Humidity

·         Acoustic Level

·         Ambient Light

External Sensor Inputs:

·         4-20mA Current Input with +20Vdc Loop

·         Digital Input (Contact Closure)

·         Counter

·         0-5Vdc Analog Input with +5Vdc Sensor Drive

 

Ambient Temperature Sensor
Temperature Range -40°C to +70°C
Typical Accuracy at 25°C ±0.3°C
Typical Accuracy over Full range ±1.4% full Span
Measurement Resolution :0.01°C
Vibration (Relative figures, Uncalibrated)
Number of Axis (averaged together) 3
Maximum Acceleration, each axis ±2G
Offset and Sensitivity Error ±10%
Measurement Resolution 0.006G
Relative Humidity
Humidity Range 5% to 95%rh
Humidity Accuracy at 25°C ±2%rh
Humidity Accuracy over Full Range ±3%rh
Measurement Resolution 0.03%rh
Acoustic Level (Relative figures, Uncalibrated)
Range 0% to 100%
Resolution 0.1%
Visible Light (Relative figures, Uncalibrated)
Range (logarithmic) 0-64000 Lux
Resolution 200 pts/Decade

External Inputs

Analog Voltage Input with 5Vdc Output
Voltage Range 0 to 5Vdc
Typical Accuracy ±0.28% full scale
Measurement Resolution 4.883 mV
Input Impedance >1 M?
Source Accuracy ±4%
Settling Time 64 mSec
Analog Current Input
Current Range 0 to 20mA
Resolution 0.020345mA
Typical Accuracy ±0.29% full scale
Loop Supply >+20Vdc, ±0.6Vdc
Settling Time 200mSec
Digital Input 1 (Pulse Counter/Contact Closure/Timer)
Zero Input Voltage 0 to 0.5Vdc (or Shorted Input)
High Input Voltage 2.4 to 10Vdc (or Open Circuit)
Count Range 216
Maximum Frequency >2500Hz counting; 40Hz Interval
Minimum Pulse Width 25mSec
Timer Range 24 Hrs
Timer Resolution 1mSec
Digital Input 2 (Pulse Counter/Contact Closure)
Zero Input Voltage 0 to 0.5Vdc (or Shorted Input)
High Input Voltage 2.4 to 10Vdc (or Open Circuit)
Count Range 232
Maximum Frequency 2500Hz
Minimum Pulse Width 200µSec

General Specifications

Physical Size
Dimensions 3.5 in x 3.25 in x 2in. (89mm x 83mm x 51mm)
Weight 8 oz. (227g)
General
Sampling Rate User Settable 30sec – 24hrs
Emergency Data Storage 250 Samples per Sensor
Power Options
Option #1 100-240Vac 50-60Hz
Option #2 DC Input 4-7Vdc
Option #3 3 x AA Batteries (6 month life at 5 minute sampling intervals)
Wireless
Range 250ft Outdoors, 90ft Indoors
Topology Mesh
Standard IEEE 802.15.4
Frequency 2.4GHz DSS
Power Output -0.79dBm
Operating Environment
Operation temperature when using Lithium batteries -40°C to 70°C, 5-95%rh
Operation temperature when using Alkaline batteries -20°C to 50°C, 5-95%rh