A1-02b Wireless Temperature Data Logger

  • Beschrijving
  • Meer details
Wireless temperature monitor that can handle various external temperature sensors.
  • Setup alarm states and receive alarms via email, cell phone, pager, or landline. Even send the same alarm to multiple locations!
  • Power or internet outage notifications
  • Internal temperature
  • External Type T thermocouple, RTD, Thermistor and 0-5V inputs
  • 1 Digital input
  • Battery or AC power
  • Up to 250' range
  • 250 Sample buffer

Neem direct contact met ons op voor een actuele aanbieding

Temperature Sensor Pod

The A1-02b Temperature Sensor Pod is designed for measuring temperature at a remote site. Right out of the box, it will measure the ambient temperature. Additionally, the screw terminal connector can be used for hooking up a high accuracy RTD or thermistor temperature sensor. A separate miniature TC connector allows the addition of a Type T thermocouple for cryogenic temperature measurements.

Package Contains:

·         A1-02 Pod

·         Pin-out Guide

·         AC Adapter

·         Standard Antenna

·         Wall Mounting Bracket

·         Batteries (3xAA)

Internal Sensors:

·         Ambient Temperature

External Sensor Inputs:

·         Type T Thermocouple

·         100ohm Platinum RTD

·         Thermistor

·         0-5Vdc Analog Input

Ambient Temperature Sensor
Temperature Range -40°C to +70°C
Typical Accuracy at 25°C ±1.4°C
Typical Accuracy over Full range ±2.1% full Span
Measurement Resolution 0.21°C
Standard Temperature Probe
Temperature Range -200°C to +200°C
Typical Accuracy ±1°C
Measurement Resolution 0.1°C
Sensor Type 1 x RTD
Thermistor
Temperature Range -40°C to +100°C
Typical Accuracy over -10°C to +50°C ±0.49°C
Measurement Resolution 0.1°C
NTC Thermistor Resistance at 25°C 10K?
Cryogenic LN2 Temperature Probe Input
Temperature Range -200°C to +400°C
Typical Accuracy over -200°C to -120°C ±1.2°C
Measurement Resolution 0.35°C
Sensor Type 1 x Type T Thermocouple
Analog Voltage Input
Voltage Range 0 to 5Vdc
Typical Accuracy ±15mV
Measurement Resolution 4.883 mV
Input Impedance >1 M
Digital Input (Pulse Counter/Contact Closure/Timer
Zero Input Voltage 0 to 0.5Vdc (or Shorted Input)
High Input Voltage 2.4 to 10Vdc (or Open Circuit)
Count Range 216
Maximum Frequency 2500Hz counting; 40Hz Interval
Minimum Pulse Width 25mSec
Timer Range 24 Hrs

General Specifications

Physical Size
Dimensions 3.5 in x 3.25 in x 2in. (89mm x 83mm x 51mm)
Weight 8 oz. (227g)
General
Sampling Rate User Settable 30sec – 24hrs
Emergency Data Storage 250 Samples per Sensor
Power Options
Option #1 100-240Vac 50-60Hz
Option #2 DC Input 4-7Vdc
Option #3 3 x AA Batteries (6 month life at 5 minute sampling intervals)
Wireless
Range 250ft Outdoors, 90ft Indoors
Topology Mesh
Standard IEEE 802.15.4
Frequency 2.4GHz DSS
Power Output -0.79dBm
Operating Environment
Operation temperature when using Lithium batteries -40°C to 70°C, 5-95%rh
Operation temperature when using Alkaline batteries -20°C to 50°C, 5-95%rh